How To Check The Oil Level Of The Reducer Apr 28, 2020

How to check the oil level of the reducer:


1. Cut off the power supply to prevent electric shock. Wait for the reducer to cool down;


2. Remove the oil level screw plug to check whether the oil is full;


3. Install the oil level screw plug.


Inspection of oil:


1. Cut off the power supply to prevent electric shock. Wait for the reducer to cool down;


2. Open the oil drain plug and take an oil sample;


3. Check the viscosity index of the oil: if the oil is obviously turbid, it is recommended to replace it as soon as possible;


4. For the reducer with oil level plug: check the oil level, whether it is qualified; install the oil level plug.


Oil replacement:


After cooling, the viscosity of the oil increases and it is difficult to drain the oil. The reducer should be changed at the operating temperature.


1. Cut off the power supply to prevent electric shock. Wait until the reducer cools down without danger of burning;


Note: The reducer should still keep warm when changing oil;


2. Place an oil receiving pan under the oil drain plug;


3. Open the oil level screw plug, ventilator and oil drain plug;


4. Remove all oil;


5. Install the oil drain plug;


6. Inject new oil of the same brand;


7. The amount of oil should be consistent with the installation location;


8. Check the oil level at the oil level screw plug;


9. Tighten the oil level screw plug and ventilator.